Two risks, one valve
A thermostatic mixing valve blends hot and cold water so the tap runs at 38 to 46°C and cannot scald. Care homes, schools, nurseries, hospitals and anywhere with very young, elderly or disabled users fit them at baths, showers and often basins. But the blended water sits below 50°C, which is the range legionella likes, so a TMV always trades one risk for another. Servicing keeps both under control.
Have TMVs and a risk assessment that says service them? Tell us how many and where. Quote within one working day.
Tell us what you needNot sure whether you need TMVs, or how many you have? The risk assessment counts them and says which are needed. Fixed price within one working day.
Get my price
What it is and what you get
HSE guidance says TMVs need regular routine maintenance by competent people, to the manufacturer's instructions, to keep protecting against scalds. The strainers or filters on each valve should be inspected, cleaned, descaled and disinfected once a year, or at the frequency your risk assessment sets.
Where vulnerable people use baths or showers and the scalding risk is significant, the valve should be a Type 3 (TMV3): pre-set and fail-safe, so it shuts off if the cold supply fails rather than letting hot water through. They must be checked regularly to confirm they still fail safe.
What a service visit covers, per valve
- Valve identified and tagged, its location and type recorded against your asset list.
- Isolate; strainers and filters removed, cleaned, descaled and disinfected; non-return valves checked.
- Mixed water temperature measured at the outlet and set to the design figure for that outlet.
- Fail-safe test, to the TMV3 scheme's in-service test: the cold supply is isolated and the outlet checked to confirm the hot flow shuts off.
- Hot and cold supply temperatures at the valve recorded, so the legionella side of the picture is in the same record.
- Any valve that fails, is scaled beyond cleaning or is the wrong type for its users is reported with a quote to replace it within one working day.
What you get
- A TMV service record for every valve: location, type, date, strainer clean, set temperature, fail-safe result, the name of the person who did it. HSE guidance says a documented maintenance schedule should be followed; this is that record.
- An asset list of your TMVs, so the next service and the next risk assessment start from the same count.
- A note of valves the risk assessment could remove. HSE guidance says assess whether each TMV is needed and, if not, remove it, because a valve nobody needs is a legionella risk with no benefit.
When you need it
- Once a year, every valve, or at the interval your risk assessment sets. That is HSE's indication and most manufacturers' too.
- When the people using the water are vulnerable. Care homes, nursing homes, hospitals, nurseries and special schools carry a significant scalding risk at baths and showers, and TMV3 valves there must be shown to fail safe.
- When a tap runs too hot or too cold. A scaled valve drifts. Too hot is a scald; too cold is legionella range and a sign the valve is not mixing.
- After a sample result downstream of a TMV. Legionella found at a blended outlet points at the valve and the pipe behind it. Samples for the system should be taken from unblended outlets; the valve gets serviced and the dead leg behind it looked at.
- Before a CQC inspection or an insurer's audit asks for the TMV records, and there are none.
- When your risk assessment lists "service TMVs" as an action. Most do where TMVs exist.
What the service is not: a reason to fit TMVs everywhere. HSE guidance says weigh the need for a TMV3 on a hand basin against legionella control. For most people, 50°C at a basin is a small scald risk that a warning sign can cover.
Your legal duties
Two duties meet at the valve. Under COSHH and ACOP L8 you must control the legionella risk, which means keeping blended water and the pipe behind the valve from becoming a warm dead leg. Under the Health and Safety at Work etc. Act you must protect people from scalding, which for vulnerable users means a fail-safe valve that is maintained.
Maintenance of control measures must be recorded. The TMV service record is one of the monitoring records ACOP L8 says to keep for at least five years.
If you do nothing, a scaled TMV can let hot water through or hold warm water for weeks. Either way the record shows the check was not done.
Priced per valve
Priced per valve, with a site minimum. Quote within one working day.
Who are the LCA?
The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.
Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.
Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day. Read more
Questions people ask
What is a TMV?
A thermostatic mixing valve: it blends hot and cold water so the tap or shower runs at a safe temperature, usually 38 to 46°C, and cannot scald. TMV3 valves are pre-set and fail safe if the cold supply fails; they are required in healthcare and where users are vulnerable.
How often should TMVs be serviced?
Once a year, or at the interval your risk assessment sets. HSE guidance says inspect, clean, descale and disinfect the strainers annually and maintain the valve to the manufacturer's instructions.
What does a TMV service include?
Strainers cleaned, descaled and disinfected; the mixed temperature checked and set; the fail-safe tested by isolating the cold supply; supply temperatures recorded; the valve tagged and logged. A failed valve is reported with a quote to replace it.
Do I need TMVs in a care home?
Where residents are vulnerable and use baths or showers, HSE guidance says TMV3 valves are required at those outlets. Basins are assessed case by case against the legionella risk. Your risk assessment says which outlets need one.
Can a TMV cause legionella?
It can help it grow. Blended water below 50°C sits in the valve and the pipe to the tap, which is the temperature legionella likes. That is why HSE guidance says fit TMVs only where the scald risk needs them, keep them close to the outlet, and service them.
Is TMV servicing a legal requirement?
Not in those words. Legislation requires you to maintain and test your control measures and keep records; a TMV is a control measure against scalding and a factor in legionella control. ACOP L8 and HSG274 say how.
How much does TMV servicing cost?
Priced per valve with a site minimum, so we quote each site within one working day. Tell us how many valves and where.
Priced per valve. Quote within one working day.
Need a legionella risk assessment first? Get my price