Our office confirms within one working day
Factory and Warehouse Legionella Risk Assessment
LCA member quality. Our most competitive price. Your exact price needs six questions: the floor area, the number of staff, and what water systems the site has.
No site visit to get a price. No account.
What a factory or warehouse must do
If you employ people or control a site, the HSE says you have a duty to understand and manage the risk from legionella. It comes from the Health and Safety at Work etc. Act 1974 and COSHH 2002, and ACOP L8 says how to meet it. There is no exemption for industrial or storage buildings. The plain-English version is on our legislation and HSE guidance page.
In practice that means four things: an assessment of where the risk is, a written scheme saying how it is controlled, someone named to run it, and records showing the checks are done. With five or more employees, the significant findings must be written down.
Who inspects you depends on what the site does. For a factory it is usually the HSE. For a warehouse that stores goods for retail or wholesale distribution it is usually the council's environmental health team. Either can ask to see your assessment and your records, and either will ask first about a cooling tower if you have one.
What your assessor looks at on a site
A site often has several separate water systems, each with its own risk. Your assessor walks all of it, not just the office block, and checks:
- The welfare block. Showers used by one shift, a canteen, washrooms on a mezzanine nobody visits. Water that stands warm for days between uses is where legionella grows.
- Emergency showers and eyebaths. Nobody uses them until the day something goes wrong. HSG274 says flush them through to drain at least every six months, drawing off three to five times the water standing in them, and more often if the risk assessment says so. Your assessor finds every one and checks the record.
- Cold water storage. Large sectional tanks in plant rooms and roof spaces, often warm in summer, sometimes with loose lids or no insulation. Cold water should stay below 20°C.
- Hot water. Calorifiers and water heaters for the welfare block. Stored hot water should be at 60°C or more, and reach 50°C at the outlet within a minute.
- Long pipe runs and dead legs. Sites change. A line that once fed a machine or a demolished building can be left full of standing water, still connected.
- Hoses, washers and process water. Wash-down hoses and hose reels in the sun, vehicle and pressure washers, and any water that is sprayed, misted or recirculated in a process. These are covered by HSG274 Part 3.
- Cooling towers and evaporative condensers. The highest-risk plant on any site, with their own rules (below).
- Who owns what. On a multi-unit estate, or where contractors run parts of the site, the report says which systems are yours and which are the landlord's or the contractor's.
You get a written report with a risk rating for each system, a schematic of the pipework and an action list in priority order. The report includes photographs of the plant and anything that needs fixing. What the report looks like, and what happens on the day, is on the legionella risk assessment page.
Cooling towers and evaporative condensers
A wet cooling tower or evaporative condenser throws a plume of fine droplets that can carry a long way downwind. That is why it is the plant behind most large outbreaks, and why the HSE's guidance for it, HSG274 Part 1, is the strictest. What it asks:
- Tell the council. The Notification of Cooling Towers and Evaporative Condensers Regulations 1992 make you notify the local authority in writing, with where the unit is, and again when it goes out of use.
- Weekly checks. The water treatment is checked weekly with dip slides, and the water is sampled for legionella at least every three months.
- Regular cleaning. Cleaned and disinfected at least twice a year for comfort cooling, at least every three months in a dirty environment, and at least once a year for a clean industrial system.
- After a shutdown. Inspected, disinfected and if need be cleaned before it is first run, and after a shutdown of a month or more.
- Drift eliminators. Kept in good order, so as few droplets as possible escape.
Not every unit on a roof is a cooling tower. Most air conditioning is dry and holds no water, and dry or adiabatic coolers may fall outside the notification rules; your assessor checks which you have. If the site has a wet tower or evaporative condenser, say so when you ask for your price. The visit is longer, so we come back to you with a quote within one working day.
Price your site
- Small unit, up to 250 m²Get my exact price
- Factory or warehouse, 250 to 1,000 m²Get my exact price
- Large site, over 1,000 m²Get my exact price
Floor area, staff numbers and the water systems on site set the price. Tell us what you have, and we email you a fixed price.
Summer and Christmas shutdowns
A two-week shutdown leaves every pipe on site full of still water. HSE guidance says a system taken out of use should be recommissioned as though it were new before people come back: thoroughly flushed, cleaned and disinfected where needed. A cooling tower idle for a month or more must be inspected and disinfected before it runs again. Plan the restart before you close, and put who flushes what, and when, in the written scheme.
Six questions. Your price. Book. Your fixed price arrives by email within one working day. Accept it with one click, and we agree your visit date with you.
Who are the LCA?
The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.
Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.
Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day. Read more
Questions people ask
Does a factory or warehouse need a legionella risk assessment?
Yes. Every employer and everyone in control of premises must assess the risk from legionella under COSHH and ACOP L8. Industrial and storage buildings are not exempt. A small unit on mains water with a few taps is low risk, and the assessment is what shows it.
Our warehouse only has toilets and a kitchen. Do we still need one?
Yes, but it will be short. The assessment records that the risk is low, lists any outlets that go unused, and sets the few checks needed. That is the document an inspector or auditor asks for.
Do emergency showers and eyebaths count?
Yes. They hold water that sits still for months and then sprays it at someone's face. HSG274 says flush them through to drain at least every six months, drawing off three to five times the water standing in them, and more often if the assessment says so.
We have a cooling tower. Can you assess it?
Yes. Say so when you ask for your price; the visit is longer, so we come back to you with a quote within one working day. Remember the tower must also be notified to the council in writing, and its water treated and checked weekly.
Who inspects legionella control on an industrial site?
For a factory it is usually the HSE. For a warehouse storing goods for retail or wholesale distribution it is usually the council's environmental health team. Both enforce the same law and ACOP L8.
Do we need the water tested?
For hot and cold water, usually not: the HSE says sampling is not normally needed unless the controls are in doubt. A cooling tower is different and must be sampled for legionella at least every three months. Testing is a separate service.
We shut for two weeks at Christmas. What do we do?
Plan the restart before you close. Outlets that stood unused are flushed before people use them, and a system out of use for longer is recommissioned as though it were new. A cooling tower idle for a month or more is inspected and disinfected first.
How much does it cost?
Floor area, staff numbers and the water systems on site set the price. You get our most competitive price, for work by an LCA member company, and we email you a fixed price.
Near you: Sheffield · Leeds · Manchester · Nottingham · London · Birmingham · Leicester · Coventry · Northampton · Milton Keynes · Luton · Bradford · Stockport · Huddersfield · Halifax · Derby · Mansfield · Doncaster · York · Hull · Lincoln · Rotherham · Barnsley · Chesterfield · Wakefield · Scunthorpe · Grimsby · Worksop · South Yorkshire · Areas we cover
Sources
- HSE, Legionella risk in water systems
- HSE, Legionnaires' disease: what you must do
- HSE, Legionella duties (including cooling tower notification)
- HSE, Reviewing what you do
- HSE, Hot and cold water systems
- HSE, Testing and monitoring
- ACOP L8 fourth edition
- HSG274 Part 1, evaporative cooling systems (paragraphs 1.14, 1.60, 1.82, 1.87)
- HSG274 Part 2, hot and cold water systems (Table 2.1; paragraphs 2.50 to 2.52, buildings taken out of use)
- HSG274 Part 3, other risk systems
- Notification of Cooling Towers and Evaporative Condensers Regulations 1992
- Health and Safety (Enforcing Authority) Regulations 1998, Schedule 1