Legionella Monitoring and Log Books. Quote within one working day.

The checks your written scheme asks for, done on a rota and recorded: temperatures, flushing, tanks, calorifiers (hot water cylinders), showers and TMVs (the valves that stop scalding). A log book that is up to date on the day someone asks to see it. Carried out by our City & Guilds qualified, LCA registered risk assessors.
How many sites?

Your quote by email within one working day · No obligation

Used only for this enquiry. No marketing lists. Privacy notice

  • Quote within 1 working day
  • Checks to HSG274 Table 2.1

Do it yourself, or have it done

Monitoring is the part of legionella control that never stops. Every month, someone has to run the sentinel taps with a thermometer, flush the outlets nobody uses, write the numbers down and act on the ones that are wrong. Many sites do it themselves. Many start that way and stop after the third month, and the HSE says a lapse can cause a sharp rise in legionella at the outlet.

Want to do it in-house? Your risk assessment lists the checks, and a half-day of training covers the rest. Legionella awareness training

  • Want it done and recorded for you? That is a monitoring contract. Tell us the site and we quote within one working day.

    Tell us what you need
  • No risk assessment yet? It comes first: it sets which checks, where and how often.

    Get my price

What it is and what you get

Monitoring means checking that your controls are working: that hot water is hot, cold water is cold, water is moving, and the plant is clean. ACOP L8 says the responsible person should oversee it, or an outside contractor can do it. How often depends on the system and who uses the water; the risk assessment sets the frequency.

The checks, and how often HSE guidance suggests them (HSG274 Table 2.1)

CheckWhat is doneHow often
Hot water sentinel outletsRun the nearest and furthest hot taps; confirm 50°C within one minute (55°C in healthcare)Monthly
Cold water sentinel outletsRun the nearest and furthest cold taps; confirm below 20°C within two minutesMonthly
CalorifierFlow temperature at or close to 60°C; return not below 50°CMonthly
Other outletsA rotating selection, so the whole system is profiled over timeRepresentative selection each visit
Little-used outletsFlush until the temperature settles, purge to drain, log itWeekly, or as the assessment says
Cold water storage tankStored water temperature and incoming mains temperatureAnnually (summer), or as profiling says
Cold water storage tankInspect condition inside and out; lid, screens, insulation, water surfaceAnnually
Calorifier internal inspectionInspect and clean by draining; purge the base where there is no hatchInspect annually; drain and purge the base as the assessment says
Point-of-use heaters (up to 15 litres)Outlet temperature 50 to 60°C, or confirm high turnoverMonthly to six-monthly, or as the assessment says
Showers and spray tapsDismantle, clean and descale heads, inserts and hosesQuarterly, or as the assessment says
TMVsStrainers inspected, cleaned, descaled and disinfected; fail-safe checkedAnnually, or as the assessment says
Thermal insulationIntact, weatherproof where outdoorsAnnually
Point-of-use filtersService dates recorded, replaced on the manufacturer's schedulePer manufacturer
Water softenersSalt levels, hardness check; service and disinfectWeekly check; service per manufacturer

Legionella temperatures, explained

What you get

  • A monitoring schedule built from your risk assessment and written scheme, not a standard list.
  • Visits on the rota the schedule sets: usually monthly, with the quarterly, six-monthly and annual tasks folded in.
  • Every reading recorded with the location, date, the name of the person, and the result against its limit. HSE guidance asks for exactly that, so a repeat reading can be taken in the same place.
  • Your log book, kept for you and laid out the way an inspector or auditor reads it.
  • A same-day warning when a reading is out of range, with what to do and a quote within one working day if it needs work.
  • The weekly flushing of little-used outlets, done by your own staff on a sheet we supply, or done for you each week if you prefer.

When you need it

You need monitoring from the day the risk assessment finds a risk you are controlling rather than removing. Temperature control only works if someone checks the temperatures; flushing only works if it is sustained and logged.

A monitoring contract is the usual answer when:

  • Nobody on site owns the log book. There is a responsible person on paper, but the checks are not happening.
  • The site has stored water, a calorifier, showers or TMVs. Those bring the quarterly and annual tasks, which need tools and someone who knows what a fouled calorifier looks like.
  • Vulnerable people use the water. Care homes and healthcare premises carry higher temperatures, more frequent flushing and a lower tolerance for lapses.
  • You have more than one site, and want one schedule, one log format and one number to call.
  • A regulator or insurer has asked to see the records. CQC for care and dental, the local authority, a landlord's insurer. An empty log book is what they find first.

What monitoring is not: a substitute for the risk assessment, or for fixing a control that keeps failing. If a sentinel is out of range every month, the answer is remedial work, not another reading. Remedial works

Your legal duties

COSHH requires you to maintain, examine and test your control measures and to keep suitable records. ACOP L8 says the written scheme must set the checks and how often they happen. The results of every monitoring inspection, test or check, with the dates, are kept for at least five years.

With five or more employees you must record the significant findings of the assessment and the steps taken; with fewer, HSE still advises a written record. Every record should be signed, verified or authenticated by the person who did the task.

Monitoring is also what tells you the assessment needs a review: results showing that controls are no longer effective are one of the triggers ACOP L8 lists.

Priced per site

Priced per site, by the number of outlets, tanks and plant, and the visit frequency. Quote within one working day.

Who are the LCA?

The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.

Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.

Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day. Read more

Questions

Questions people ask

What is a legionella log book?

The record of every check on your water system: temperatures at sentinel outlets, flushing of little-used outlets, tank and calorifier inspections, TMV services, and what was done when a reading was wrong. ACOP L8 says keep monitoring records for at least five years.

How often should legionella temperature checks be done?

Monthly at the sentinel outlets, with a rotating selection of other outlets, is HSE's indication for hot and cold water systems. Little-used outlets are flushed weekly. Your risk assessment can set a different frequency for your site.

What temperatures should I record?

Hot water stored at 60°C or above and reaching 50°C at the tap within a minute (55°C in healthcare). Cold water below 20°C within two minutes of running. Calorifier return not below 50°C.

Legionella temperatures, explained

Can I do legionella monitoring myself?

Yes, if the person doing it is trained and the checks are sustained and recorded. The risk assessment lists the checks; a half-day awareness course covers the how.

Legionella awareness training

What is a sentinel outlet?

The nearest and furthest outlets from the tank or calorifier on each branch or loop. If those two are in range, the pipe between them usually is too. Your risk assessment names them.

How much does a legionella monitoring contract cost?

It depends on outlets, plant and the visit frequency, so we quote each site within one working day. A legionella risk assessment, by contrast, has a fixed price within one working day.

Get my price

Does monitoring include legionella testing?

Not by default. Sampling is only advised when the assessment or the readings call for it, and is quoted separately.

Legionella testing and water sampling

Priced per site. Quote within one working day.

Tell us what you need

Need a legionella risk assessment first? Get my price

Who are the LCA?

The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.

Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.

Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day.

Read more