Our office confirms within one working day

GP Surgery and Clinic Legionella Risk Assessment

Carried out by our City & Guilds qualified, LCA registered risk assessors. · Visit date agreed with you.
How many sites?

Your quote by email within one working day · No obligation

Used only for this enquiry. No marketing lists. Privacy notice

LCA member quality. Our most competitive price. Your exact price needs six questions: the floor area, the number of rooms, and how hot water is made.

No site visit to get a price. No account.

Not sure if you need one?

What CQC expects of a GP practice

CQC's own guidance for GP practices says it expects practices to give assurance that they have carried out risk assessments to identify all the risks associated with their premises, and that they are managing those risks. For water, the guidance it points to is the HSE's on controlling legionella.

Its mythbuster on legionella says every water system needs a risk assessment, but not every system needs elaborate controls. In many practices the assessment concludes the risk is low and properly managed, and then the job is done. What inspectors want is the document that shows it, the record of the checks, and someone in the practice who knows what both say.

Underneath CQC sits the same law as every workplace: the Health and Safety at Work etc. Act 1974, COSHH 2002 and ACOP L8. Patients who are older, smokers, or living with chronic lung or kidney disease or a weak immune system are the people the HSE names as most at risk, and they are in your waiting room every day. The plain-English version of the duty is on our legislation and HSE guidance page.

What your assessor looks at in a surgery

Most surgeries are small, mostly cold-water buildings, and the risk sits in a few predictable places. Your assessor walks every room and checks:

  • Rooms that go unused. A consulting room held for a visiting clinician, a minor surgery room, a staff shower, an accessible toilet. Any outlet that goes a week unused should be flushed every week, and the report lists every one.
  • Clinical hand-wash basins. Often fitted with sensor taps and thermostatic mixing valves. Blended water just below the valve sits at the temperature legionella likes, so the valves are serviced and the outlets kept in use.
  • How hot water is made. Under-sink heaters, a combi, or a cylinder. Stored hot water should be at 60°C or more. In healthcare premises the HSE's guidance asks for 55°C at the outlet within a minute, higher than the 50°C for other buildings.
  • Cold water. Mains in most purpose-built centres; a loft tank in many surgeries that started life as houses. Cold water should stay below 20°C.
  • Drinks and kitchen equipment. Water coolers, boiling taps and plumbed-in coffee machines all hold water. They are listed and checked.
  • Who controls what. In a shared health centre the landlord often manages the tanks and plant and each practice the outlets in its rooms. The report states where the line is.

You get a written report with a risk rating for each system, a schematic of the pipework and an action list in priority order, the evidence CQC asks for. The report includes photographs of the plant and anything that needs fixing. What the report looks like, and what happens on the day, is on the legionella risk assessment page.

Do GP surgeries have to follow HTM 04-01?

HTM 04-01, Safe water in healthcare premises, is NHS England's best-practice guidance for water in healthcare buildings. It is written with hospitals and large estates in mind: water safety groups, water safety plans, an authorising engineer. It is not law, and CQC's GP guidance points to the HSE's guidance rather than to HTM 04-01.

For a small surgery, what matters from it is proportionate: the higher outlet temperatures for healthcare, thermostatic mixing valves serviced and their outlets used, and records kept. A large health centre, or a building where NHS standards are written into the lease, may be expected to follow it more fully. Tell us when you ask for your price, and your assessor works to the standard your building needs.

Price your practice

Floor area, the number of rooms and how hot water is made set the price. Tell us what you have, and we email you a fixed price.

When to book one, or review yours

  • you take on new premises, or a CQC registration needs the assessment;
  • you fit a new consulting room, basin, shower or accessible toilet, or move plumbing;
  • rooms stand empty because sessions or services change;
  • the building has been closed and you are reopening it;
  • the last assessment is past its review date, cannot be found, or its actions were never closed;
  • a CQC inspection is coming and you cannot put your hands on the report.

The HSE does not set a fixed interval. It says review the assessment regularly, and at once when there is reason to think it no longer holds. Your report gives your review date. The full answer is in our guide to how often you need a legionella risk assessment.

Six questions. Your price. Book. Your fixed price arrives by email within one working day. Accept it with one click, and we agree your visit date with you.

A dental surgery in the same building?

Dental chairs have waterlines with their own rules (HTM 01-05). If the centre has a dental surgery, say so when you ask for your price; the details are on our dental practices page.

Who are the LCA?

The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.

Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.

Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day. Read more

Questions

Questions people ask

Does a GP surgery need a legionella risk assessment?

Yes. Every employer and everyone in control of premises must assess the risk from legionella under COSHH and ACOP L8, and CQC expects GP practices to show they have assessed and are managing the risks of their premises.

Get my price

Will CQC ask to see it?

It can. CQC looks for assurance that premises risks, legionella among them, have been assessed and are being managed. Keep the report, the action list and the records of your checks where you can find them.

Who can carry out the assessment?

CQC's guidance says neither it nor the HSE sets any requirement about who carries it out, other than that they are competent. Our City & Guilds qualified, LCA registered risk assessors carry out the assessment and write the report.

Get my price

Do we have to follow HTM 04-01?

HTM 04-01 is NHS best-practice guidance, not law, and is written mainly for larger estates. A small surgery uses it proportionately: higher outlet temperatures, serviced mixing valves, good records. A large health centre or an NHS lease may expect more.

We rent from a landlord in a health centre. Whose duty is it?

Usually both. The landlord manages the shared tanks and plant; the practice is responsible for the outlets it controls. Ask for the building's assessment, check your rooms are on it, and get one for your rooms if they are not.

Do we need the water tested?

Usually not. The HSE says sampling is not normally needed for hot and cold water systems unless the controls are in doubt. The assessment tells you where the risk is; a test tells you what was in one sample on one day. Testing is a separate service.

Tell us what you need

How often should a surgery review it?

Regularly, and at once after any change, such as a new room, a new basin or a building that has stood empty. There is no fixed period; your report gives your review date.

How often, in full

How much does it cost?

Floor area, the number of rooms and how hot water is made set the price. You get our most competitive price, for work by an LCA member company, and we email you a fixed price.

Get my price

About 2 minutes · No account · No obligation

Who are the LCA?

The Legionella Control Association (LCA) is a UK body for companies that provide legionella control services. It was founded in 1999 by the Water Management Society and the British Association for Chemical Specialities (now the BCA). Member companies are audited when they join and every year after that. The audit is against the LCA Code of Conduct and its Service Standards, and covers only the services they have registered. A company is only listed while it appears on the LCA directory.

Your assessment is carried out by our City & Guilds qualified, LCA registered risk assessors. The registration is shown on your quotation, and you can check it on the LCA directory.

Registration shows a company works to an audited standard. It is not a guarantee, and the LCA does not assess individual staff, so we also show you exactly what is included and what happens on the day.

Read more